Wednesday, October 3, 2012

SBL-JCA-00313: Socket had incorrect word size: {0}.





Applies to:


Siebel System Software - Version 7.8.2.5 [19227] and later
z*OBSOLETE: Microsoft Windows Server 2003

Product Release: V7 (Enterprise)

Version: 7.8.2.5 [19227]

Database: Oracle 10.1.0.4

Application Server OS: Microsoft Windows 2003 Server SP1

Database Server OS: Sun Solaris 9



This document was previously published as Siebel SR 38-3388527211.

""""Checked for relevance on 23-MAY-2012""""







Symptoms


The connections from webMethods to Siebel are intermittently failing
with an error code 8234 on webMethods. Here is a sequence of events
observed in logs:

1. webMethods attemps to login and open a connection.

2. a new session is instantiated in Siebel and waits, but does not proceed with authentication.

3. webMethods request reports 8234 with a timeout after 2 mins.

4. webmethods opens another connection. This goes through successfully.

5. The first Siebel session terminates with a timeout after 45 mins.



The siebel log prints the typical parameters for the session and then the following two statements:





2021
2007-06-28 16:21:23 2007-06-28 17:06:24 -0400 0000014a 001 003f 0001 09
eMediaObjMgrWM_enu 25802 4040 6004
D:\sea78\siebsrvr\log\eMediaObjMgrWM_enu_25802.log 7.8.2.5 [19227] ENU

TaskConfig    TaskCfgParamInit    4    0    2007-06-28 16:21:23    The Parameters for the current task are :

TaskConfig    TaskCfgParamInit    4    0    2007-06-28 16:21:23        Enterprise                                    : SiebelINT

TaskConfig    TaskCfgParamInit    4    0    2007-06-28 16:21:23        Server                                        : SBINT2

TaskConfig    TaskCfgParamInit    4    0    2007-06-28
16:21:23        Siebel Home                                   :
D:\sea78\siebsrvr

....

prints other parameters

...

TaskConfig    TaskCfgParamInit    4    0    2007-06-28 16:21:23        Eligibility Display Mode                      : 1

TaskEvents    TaskCreation    3    0    2007-06-28 16:21:23    Created
context for task 25802 with session timeout = 2700 (thrdId 6004,
timestamp 1183062083)

TaskEvents    TaskTimeout    3    0    2007-06-28 17:06:24    SBL-SMI-00126: The session has timed out.





Further investigation in the Webmethods logs showed the following errors:







2007-06-28 13:02:12 EDT [ISC.0066.0024V5] FSMTValuesHash.getEntryLock(): id=24381839 lock request granted

2007-06-28 13:02:14 EDT [ART.0114.1007E] Adapter Runtime: Error Logged.
See Error log for details. Error: [ADA.448.1000]
SiebelJavaConnection.connectFromValues -
dataBean.login(siebel.tcpip.none.none://sbwsint01:2321/SiebelINT/eMediaObjMgrWM_enu)
threw a SiebelException: code(8234), msg(Logon Request 394 was
abandoned after 68991 ms. Connection: 6481 due to connection shutdown
request Connection timed out (SBL-JCA-303) )

2007-06-28 13:02:14 EDT [SCC.0126.0119E] An error occurred while
attempting to create connections for
IEEEBMSConnections.Siebel:Siebel_eMedia

2007-06-28 13:02:14 EDT [SCC.0126.0106E] An error occurred while
attempting to retrieve a connection from
IEEEBMSConnections.Siebel:Siebel_eMedia

2007-06-28 13:02:14 EDT [SCC.0126.0202V1] SCC ConnectionManager pool IEEEBMSConnections.Siebel:Siebel_eMedia reset

2007-06-28 13:02:14 EDT [ART.0114.1007E] Adapter Runtime: Error Logged.
See Error log for details. Error: [ART.118.5053] Adapter Runtime
(Connection): Unable to get a connection to resource
IEEEBMSConnections.Siebel:Siebel_eMedia.

[ADA.448.1000] SiebelJavaConnection.connectFromValues -
dataBean.login(siebel.tcpip.none.none://sbwsint01:2321/SiebelINT/eMediaObjMgrWM_enu)
threw a SiebelException: code(8234), msg(Logon Request 394 was
abandoned after 68991 ms. Connection: 6481 due to connection shutdown
request Connection timed out (SBL-JCA-303) )

2007-06-28 13:02:14 EDT [ART.0114.1007E] Adapter Runtime: Error Logged.
See Error log for details. Error: [ART.117.4012] Adapter Runtime
(Adapter Service): Unable to run adapter service. Error occurred when
connecting to resource IEEEBMSConnections.Siebel:Siebel_eMedia.

[ART.118.5053] Adapter Runtime (Connection): Unable to get a connection to resource IEEEBMSConnections.Siebel:Siebel_eMedia.

[ADA.448.1000] SiebelJavaConnection.connectFromValues -
dataBean.login(siebel.tcpip.none.none://sbwsint01:2321/SiebelINT/eMediaObjMgrWM_enu)
threw a SiebelException: code(8234), msg(Logon Request 394 was
abandoned after 68991 ms. Connection: 6481 due to connection shutdown
request Connection timed out (SBL-JCA-303) )















Cause


This customer was using a connector developed by webmethods, which
uses the underlying technology of "Siebel Java Data Beans" to connect to
the siebel object manager.



A thorough review of java data beans timeout settings has not helped.



Java Data Beans timeouts are described at

Transports and Interfaces: Siebel Enterprise Application Integration
> Integrating with Java > About Running the Java Data Bean >Connection Parameters for the SiebelDataBean



They did not help though.









PLEASE NOTE: siebel.properties file is not the first in precedence.

If the java code provides values for these parameters, they are used.

If the java code does not provide values, the next step is to look up siebel.properties. If found, it is used.

If not found, then default values described in the above bookshelf reference apply.

See also Utilizing the siebel.properties did not succeeded in our J2EE application (Doc ID 536387.1)





The customer network experts further investigated the issue and found
out there were timeout settings at a firewall between the 2
applications:



"We worked with our network team to install a sniffer, capture tcp
traces on the webMethods servers, review them along with the logs from
Siebel and webMethods.

The traces show retransmissions and a reset on the tcp ports at times of
failure and the problem seems to be with either webmethods
adapter/Siebel java data bean trying to communicate on tcp ports that no
longer have an active Siebel session on the other end or our network
configuration with a firewall and two routers in between these two
servers blocking reuse of the tcp ports.



We seem to run into this condition because webMethods adapter does not
honor the expire timeout and close the connection nor recognize the
termination of the target Siebel session."









Conclusion :

"the connections are getting dropped due to a timeout setting on our
firewall. We have not seen any connection failures after we increased
the timeout."









Solution


Increase the timeout settings of the firewall between the 2 applications.



Please notice Oracle support policy for 3rd party java adapters at



847669.1: J2EE Adapters for Siebel : TIBCO, Webspehere, Weblogic, WebMethods, Oracle Fusion Middleware Adapters for Siebel


References


NOTE:536387.1 - Utilizing the siebel.properties did not succeeded in our J2EE application
NOTE:847669.1 - J2EE Adapters for Siebel : TIBCO, Webspehere, Weblogic, WebMethods, Oracle Fusion Middleware Adapters for Siebel








Applies to:


Siebel Tools, SPE - Version 8.1.1.4 SIA [21225] to 7.7.2.12[18393] [Release V8 to V7]
z*OBSOLETE: Microsoft Windows Server 2003

Product Release: V7 (Professional)

Version: 7.7.2.3 [18361]

Database: IBM DB2/390 V7

Application Server OS: Microsoft Windows 2003 Server

Database Server OS: IBM OS/390



This document was previously published as Siebel SR 38-3073684811.



Checked for relevance on 08-16-2012



Symptoms


We have started having occasional problems with the Siebel Java Data Bean interface.



The following errors are in the logs and we can not find any reference to them on Siebel Support.



[6/21/06 2:12:36:685 CDT] 2815670b SystemErr     R java.net.SocketException: Connection reset

[6/21/06 2:12:36:685 CDT] 2815670b SystemErr     R     at java.net.SocketInputStream.read(SocketInputStream.java(Compiled Code))

[6/21/06 2:12:36:685 CDT] 2815670b SystemErr     R     at com.siebel.om.conmgr.e.a(Unknown Source)

[6/21/06 2:12:36:685 CDT] 2815670b SystemErr     R     at com.siebel.om.conmgr.e.run(Unknown Source)

[6/21/06 2:12:36:685 CDT] 2815670b SystemErr     R     at java.lang.Thread.run(Thread.java:568)

[6/21/06 2:12:36:685 CDT] 2815670b SystemErr     R [CMGR FATAL] Error:
java.net.SocketException: Connection reset connection:e64e



This error does not always occur and is difficult to recreate.





Thx!



Cause


siebel.conmgr.poolsize was not optimally set for the customer environment.



Solution


For the benefit of other readers:



Customer was using Java Data Bean and occasionally they were encountering SBL-JCA-303 error.



The suggestion given was to increase the siebel.conmgr.poolsize in
Siebel.properties file. The default is 2. Customer increased this to 20
and no longer saw the error.










Applies to:


Siebel Email Marketing Server - Version 7.8.2.3 [19221] to 8.1 [21039] [Release V7 to V8]
z*OBSOLETE: Microsoft Windows Server 2003

Product Release: V7 (Enterprise)

Version: 7.8.2.3 [19221]

Database: Oracle 10.1.0.2

Application Server OS: Microsoft Windows 2003 Server SP1

Database Server OS: Sun Solaris 10



This document was previously published as Siebel SR 38-3188389415.







Symptoms


SBL-JCA-00207, SBL-JCA-00303


Follow up to SR 38-3178920311



The problem was the object manager had reached the maximum number of
connections allowed. Clearing the connections has resolved the new
problem. I have the service running now and will monitor.



I am concerned about the connections to the marketing object manager
maxing out. It seems that the ESD, BHD, and CTD are not releasing their
connection to the object manager when the service stops. Can you comment
on how the connections are released by these services?



Cause


Change Request #12-SZH78B was logged as a Product Defect



Solution



Message 1


For the benefit of other readers.



The customer was encountering an issue where the Bound Handler Daemon
(BHD) appeared to have connection issues with the Object Manager. After
increasing the logging the following error was shown in the logs:-



ERROR ThreadPool com.siebel.sem.smtpd.thread.ThreadPool$PoolWorker@a7ff48 caught throwable Java Lang Exception



Change Request #12-SZH78B was logged as a Product Defect



In order to workaround the issue, please perform the following:-



1) Stop the BHD Service



2) Open a CMD prompt and navigate to the ${BHD} directory



3) Type : install-win32-service.bat -uninstall



This will uninstall the BHD service



4) Edit the install-win32-service.bat using notepad



You then need to enter the following line as a parameter passed to the JVM:-



"-Dcom.siebel.sem.bouncenoSpecialHeaders=t"



So for example the string will look like:-



"%CATALINA_HOME%\bin\tomcat.exe" -install %SERVICE_NAME%
"%JAVA_ROOT%\jre\bin\server\jvm.dll" -Dfile.encoding=UTF8
-Djava.class.path="%CATALINA_HOME%\bin\bootstrap.jar;%JAVA_ROOT%\lib\tools.jar"
-Dcatalina.home="%CATALINA_HOME%"
-Dcom.siebel.sem.bouncenoSpecialHeaders=t %JVM_MEM_SWITCHES% -start
org.apache.catalina.startup.BootstrapService -params start -stop
org.apache.catalina.startup.BootstrapService -params stop -out
"%CATALINA_HOME%"\logs\stdout.log -err "%CATALINA_HOME%"\logs\stderr.log
-current "%CATAL



<< Continued ..... >>



Message 2


<< ... continued >>



The value "-Dcom.siebel.sem.bouncenoSpecialHeaders=t” is before the “%JVM_MEM_SWITCHES%” parameter.



5) Save the changes to the install-win32-service.bat file



6) Type : install-win32-service.bat



This will re-install the service



7) Start the BHD service





Regards,






Applies to:


Siebel Email Marketing Server - Version: 8.1.1.5 [21229] and later   [Release: V8 and later ]
Information in this document applies to any platform.

Problem : Click Through Daemon 8.1.1.5 Service is not created after installation on Windows 2008 server



JDK - jdk-6u1-windows-i586-p

CTD - ctd-8112-616-install



I have sucessfully installed BHD and services are starting on EMS 616.



Symptoms


CTD log:

2011-11-06 21:15:08,646 [QueueReader-0-clickQ] ERROR ClickthroughProcessor

Error
Message: Logon Request 22 was abandoned after 21562 ms. Connection:
30f009ca due to connection shutdown request Connection
reset(SBL-JCA-00303)Detailed Message:
<com.siebel.om.sisnapi.RequestException>

...        
ErrMsg>Logon Request 22 was abandoned after 21562 ms. Connection:
30f009ca due to connection shutdown request Connection
reset(SBL-JCA-00303)



stderr log:

INFO: Jk running ID=0 time=16/15 config=D:\ctd\conf\jk2.properties
java.net.SocketException: Connection reset
...
at java.net.SocketInputStream.read(SocketInputStream.java:168)
at com.siebel.om.conmgr.Connection.readPacket(Connection.java:548)
at com.siebel.om.conmgr.Connection.run(Connection.java:286)
at java.lang.Thread.run(Thread.java:595)
[CMGR FATAL] Error: java.net.SocketException: Connection reset connection:30f009ca
[CMGR WARNING] Removing connection pool siebel.TCPIP.None.None://RETDAYAPPP017:2321/LNSBLProdEnt/SMObjMgr_enu/!7.2ec0
java.net.SocketException: Connection reset


Changes


none


Cause


a file with a .bat extension (install-win32-service.bat)


Solution


The customer resolved the case by doing the below steps:
To have the Windows service for CTD component created please do the following:

1. Go to the base installation folder for CTD.
2. Look for a file with a .bat extension (install-win32-service.bat)
3. Activate this file by double clicking the file.

thank you


No comments: